اکثر مکاتبات کومش از طریق ایمیل سایت می باشد. لطفا Spam ایمیل خود را نیز چک نمایید.
   [Home ] [Archive]   [ فارسی ]  
:: ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
Subscription::
Contact us::
Site Facilities::
Webmail::
Editorial Board::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 10, Issue 2 (11-1387) ::
Koomesh 1387, 10(2): 101-110 Back to browse issues page
Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry
A. A. شرفی , M. مختاری‌دیزجی , N. مخلصیان , B. لاریجانی , A. کاظم‌نژاد
Abstract:   (12006 Views)
Introduction: Dual X-ray absorptiometry (DXA) is one of the most widely used techniques for non-invasive assessment of bone status. Radiation dosimetry is well established technique for pencil beam and fan beam DXA system, for the assessment of the surface absorbed dose. No published assessment of the absorbed dose for the various depths of the critical organs such as the thyroid and uterus was found. Therefore, in this study, we measured the surface dose and depth dose of critical organs to determine the correlation between the depth dose and the surface dose. Materials and Methods: A Lunar DPX-MD (pencil beam) system was used in this study. An anthropomorphic phantom was designed. AP spine and femur scan modes were used to measure the surface and depth doses of the thyroid left and right lobes and uterus in various deeps and scan centers. TLDs-400 were placed at the surface, near the source and also inserted at different depths in thyroid and uterus of the anthropomorphic phantom. Absorbed doses were measured on the phantom for AP spine and femur scans. The correlation between the absorbed dose and the depth was found using the linear regression analysis. Results: There was no significant correlation between the depth dose and the scan center dose except in the femur scan. AP spine effective dose were calculated as 0.064, 0.059, 0.061 and 0.242 µSv for thyroid left, right lobes, uterus and ovary, respectively. Conclusion: It is concluded that there is significant correlation between the surface and the dose of various depths of the scanned sections.
Keywords: Dual X-ray absorptiometry, Dosimetry, Phantom, Depth dose, Critical organs.
Full-Text [PDF 281 kb]   (5898 Downloads)    
Type of Study: Research | Subject: General
Received: 2009/05/4 | Accepted: 2015/02/9 | Published: 2015/02/9
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

شرفی A A, مختاری‌دیزجی M, مخلصیان N, لاریجانی B, کاظم‌نژاد A. Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry. Koomesh 1387; 10 (2) :101-110
URL: http://koomeshjournal.semums.ac.ir/article-1-458-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 10, Issue 2 (11-1387) Back to browse issues page
کومش Koomesh
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4645