Measurement of surface dose in external radiotherapy of brain frontal lobe: A study on patient and phantom
Hamide Nazemi Gelyan , Yasha Makhdumi , Alireza Nikoofar , Hadi Hasanzadeh
Abstract:   (7148 Views)
Introduction: Radiotherapy plays an important role in the treatment of most malignant and also benign primary CNS tumors. Radiotherapy affects both tumor cells and normal cells. The aim of this study was to determine the absorbed dose of radiation by the skin surfacing organs at risk (lens, parotid, thyroid and submandibular gland) during radiotherapy of tumors at the frontal lobe of the brain via direct measurement in patients and phantom. Materials and methods: There are two conventional techniques for external radiotherapy of patients with tumors of the right frontal lobe. These techniques were used to estimate the amount of surface dose absorption by organs at risk (lens of eye, parotid, thyroid, submandibular glands). Technique 1 was performed for 10 patients who referred to Reza Radiation Oncology Center. Technique 1 is the radiation of frontal field with an extension to the lateral field portion. Technique I and 2, which included radiation of one frontal field along with a bilateral field were performed for a phantom model with an anthropomorphic head and neck constructed from natural human bone with paraffin wax and NaCl as surrounding soft tissues. The surface dose for each organ was measured using TLD chips. Results: The measured radiation dose within all organs was within the safe limits in phantom and most patients, however, the surface dose were higher in patients in compare to phantom. In some patients, the right lens was not protected and therefore there would be some risk for cataracts. The findings provide estimation for probable complications along with frontal lobe radiotherapy. Conclusion: Our findings showed that regarding these two techniques, technique I impose less harm to normal tissue, since the right lobe of brain is only irradiated. Besides, the higher values of surface dose in patients compared to phantom might be due to larger tumor field in patients, because the tumor dimensions in phantom was considered 4 cm, while in some patients it was larger
Keywords: Brain Neoplasms, Radiotherapy, Radiometry, Phantoms Imaging, Radiation Dosage, Organ at Risk
Full-Text [PDF 661 kb]   (1310 Downloads)    
Type of Study: Research | Subject: General
Received: 2015/01/31 | Accepted: 2015/10/6 | Published: 2015/12/14
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nazemi Gelyan H, Makhdumi Y, Nikoofar A, Hasanzadeh H. Measurement of surface dose in external radiotherapy of brain frontal lobe: A study on patient and phantom. Koomesh 1394; 17 (2) :323-328
URL: http://koomeshjournal.semums.ac.ir/article-1-2753-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 2 (جلد 17 (2). پياپی (58). زمستان 1394 1394) Back to browse issues page
کومش Koomesh
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4660