اکثر مکاتبات کومش از طریق ایمیل سایت می باشد. لطفا Spam ایمیل خود را نیز چک نمایید.
   [Home ] [Archive]   [ فارسی ]  
:: ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
Subscription::
Contact us::
Site Facilities::
Webmail::
Editorial Board::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 6, Issue 4 (5-1384) ::
Koomesh 1384, 6(4): 319-324 Back to browse issues page
Assessment the effects of scanning and technical parameters on the detection of pulmonary nodules at different computed tomography systems
A. شمس‌آبادی , M. A. عقابیان , N. ریاحی‌عالم , K. فیروزنیا
Abstract:   (13367 Views)
Introduction: Computed tomography (CT) is the most sensitive imaging technique for the detection of pulmonary nodules and metastases, and may reveal peripheral nodules as small as 2 mm in diameter. Detection of metastases would influence treatment. CT is also useful for planning biopsy or surgical resection of putative metastases. It is therefore important to optimize the CT scanning protocol, with the goal of maximizing the sensitivity and specificity of detecting pulmonary nodules while minimizing patient dose to ionizing radiation. Materials and Methods: The chest phantom that we used made of clear transparent plastic that has inside shape and dimensions of a sheep thorax to hold simulated nodules-lung preparation of a sheep. The number of lesions per lung ranged from 40 to 50 that sized 1mm to 5 mm at two categories calcified and soft tissue (myocardium tissue).the approximate sites of implantation and the sizes of the lesions were documented. These maps later served as references for nodule detection. To simulate the radiation-absorbing qualities, Urine bags are filled with solution 15grm iodine/lit water (20mlit urografin %76 per one liter water). The phantoms are inflated through tracheal tubes during the experiment. The CT scans are obtained by using three systems at same technical and exposure parameters. Radiologist reported the images. Results: Probability of nodules detection at three CT scan systems for slice thickness, 2 mm in comparing with slice thicknss,10mm and also 5mm differed significantly (p
Keywords: Pulmonary nodules, CT Image quality, Lung neoplasm, Conventional & Spiral CT.
Full-Text [PDF 883 kb]   (27082 Downloads)    
Type of Study: Applicable | Subject: General
Received: 2008/09/10 | Published: 2005/08/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

شمس‌آبادی A, عقابیان M A, ریاحی‌عالم N, فیروزنیا K. Assessment the effects of scanning and technical parameters on the detection of pulmonary nodules at different computed tomography systems. Koomesh 1384; 6 (4) :319-324
URL: http://koomeshjournal.semums.ac.ir/article-1-133-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 6, Issue 4 (5-1384) Back to browse issues page
کومش Koomesh
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4660