Effect of a sedation guideline on the duration of mechanical ventilation and length of stay in intensive care unit
Hassan Babamohamadi , Fatemeh Tangestani , Mohsen Soleimani , Saeed Abbasi Dorche
Abstract:   (5450 Views)
Introduction: Achieving an adequate level of sedation for patients who receive mechanical ventilation is a big critical care challenge. This study aimed to determine the effect of sedation guideline on the duration of mechanical ventilation and length of stay in intensive care unit (ICU) patients. Materials and Methods: This clinical trial study was conducted in an ICU located in Isfahan, Iran, from September 2012 to February 2103. A sedation guideline was developed based on the recent 10 years existing literatures as well as the recommendations of the practicing anesthesiologists and nurses. Coresspondingly, fifty patients who had undergone abdominal surgery with vertical incision and were receiving mechanical ventilation were recruited by convenience sampling method and divided to treatment (guideline) and control (routine) groups. At first, twenty five patients (need to sedation based on Richmond scale) were sedated by using the routine sedation method. The remaining 25 patients were treated by sedation guideline. The two groups were compared in terms of duration of mechanical ventilation and length of stay in ICU. Data collection tools were include patients’ demographic characteristics questionnaire, APACHE II, Richmond scale, the dose of administered sedatives, the duration of mechanical ventilation and length of ICU stay. Results: About 76% of the participants were male. The mean of the participants’ age was 53.3. The mean of mechanical ventilation duration in the control group was significantly different from the treatment group (220.80±91.4 vs. 116.4±96.4 hours P value
Keywords: Clinical guideline, Mechanical ventilation, Length of stay, Intensive Care Unit, Sedative
Full-Text [PDF 795 kb]   (1395 Downloads)    
Type of Study: Research | Subject: General
Received: 2016/08/24 | Accepted: 2016/12/7 | Published: 2017/03/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Babamohamadi H, Tangestani F, Soleimani M, Abbasi Dorche S. Effect of a sedation guideline on the duration of mechanical ventilation and length of stay in intensive care unit . Koomesh 1396; 19 (2) :380-390
URL: http://koomeshjournal.semums.ac.ir/article-1-3501-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 19, Issue 2 (بهار 1396، شماره 19 (2). 1396) Back to browse issues page
کومش Koomesh
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4645