Evaluation of time-stability response of gelatin-Trimesic acid dosimeter
Zohreh Hoseinpour Yektaei , Ramzan Ali Ramzanpour , Maryam Rahbar , Hadi Hasanzadeh
Abstract:   (4342 Views)
Introduction: One of the problems in chemical dosimeters such as Trimesic acid is the liquid environment which makes it difficult to use. Chemical dosimeter merged into a bed of gel can help to partly overcome this problem.According to the importance of stability of dosimeter response after irradiation, in this study, the parameters of gelatin- Trimesic acid dosimeter in the range of doses of a one fraction of radiotherapy was assessed in days one, two, three and four after irradiation. Materials and Methods: After the gel construction at a concentration of 1 mM and a pH of 2.2, it was poured into Perspex vials which opening was tight with parafilm and wrapped in an aluminum foil to eliminate light and was divided into 5 groups to be irradiated with 6 MV photons of linac 24h after the gel synthesis. To do so, vials were place at the isocenter of the linac in a SSD of 100cm and field size of 10×10 cm2. The delivered doses were from 0-200 cGy and vials were kept at the temperature of 4˚C after the irradiation. The procedure of reading the vials were performed using a spectroflourimeter (Jasco 6200) from one to four days after irradiation in excitation wavelengths of 370, 380, 390, 410, 420 and 450 nm. Results: After obtaining the emission spectrum from the spectroflourimeter, the emission spectrum was analyzed and it was found that there is a peak in the wavelengths of 377, 387, 396, 416, 427 and 457 nm seen in one day after irradiation and the most stable response belongs to the first day after irradiation. Conclusion: The results of this study showed that the combined gelatin- Trimesic acid dosimeter in the first day after irradiation has the highest and most stable response and according to its characteristics, has the potential to be assessed as a clinical dosimeter
Keywords: Chemical dosimetry, Gelatin- Trimesic acid, Stability, Spectroflourimetry
Full-Text [PDF 725 kb]   (1125 Downloads)    
Type of Study: Research | Subject: General
Received: 2016/02/7 | Accepted: 2016/08/2 | Published: 2016/09/21
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Hoseinpour Yektaei Z, Ramzanpour R A, Rahbar M, Hasanzadeh H. Evaluation of time-stability response of gelatin-Trimesic acid dosimeter. Koomesh 1395; 18 (1) :159-164
URL: http://koomeshjournal.semums.ac.ir/article-1-3236-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 18, Issue 1 (پائیز 1395: جلد 18 شماره (1) 1395) Back to browse issues page
کومش Koomesh
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4645