اکثر مکاتبات کومش از طریق ایمیل سایت می باشد. لطفا Spam ایمیل خود را نیز چک نمایید.
   [Home ] [Archive]   [ فارسی ]  
:: ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
Subscription::
Contact us::
Site Facilities::
Webmail::
Editorial Board::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 23, Issue 1 (زمستان 1399) ::
Koomesh 1399, 23(1): 64-71 Back to browse issues page
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Samaneh Mostafapour , Hossein Arabi
Abstract:   (2680 Views)
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, it's crucial to generate a pseudo-CT (Computed Tomography) image from MRI for the task of MR-guided attenuation correction and RT planning. This study set out to investigate the performance of two state-of-the-art atlas-based pseudo-CT generation approaches from MR brain images. Materials and Methods: Bone segmentation was performed on 43 brain CT and MR pairs using atlas-based local weighting (Atlas-LW) and atlas registration combined with pattern recognition (AT-PR) techniques. The accuracy of bone extraction performed by these two approaches was investigated for the entire bony structures as well as cortical bone using standard segmentation metrics such as Dice similarity (DSC). Moreover, the accuracy of the CT value estimated from MR images was evaluated using mean absolute error (MAE), and root mean square error (RMSE) metrics. Results: Overall, Atlas-LW technique exhibited higher segmentation accuracy resulting in DSC=0.79±0.61 and 0.84±0.03, while AT-PR method led to DSC=0.72±0.8 and 0.77±0.05 for cortical and total bone, respectively. Moreover, Atlas-LW approach estimated CT values for the total bone tissue with MAE=17.6±138.0 HU and RMSE=466.2±75.0 HU compared to MAE=-10.9±147.0 HU and RMSE=522.5±89.7 HU obtained from AT-PR approach. Conclusion: The Atlas-LW exhibited superior the performance in this study which demonstrates its potential to be employed in PET/MR attenuation correction (AC) and MR-only RT planning
Keywords: Bone, Brain, Magnetic Resonance Imaging, Positron-Emission Tomography, Radiotherapy
Full-Text [PDF 1121 kb]   (622 Downloads)    
Type of Study: Research | Subject: General
Received: 2020/01/20 | Accepted: 2020/07/12 | Published: 2021/01/12
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA

Ethics code: 241345CH



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mostafapour S, Arabi H. Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction. Koomesh 1399; 23 (1) :64-71
URL: http://koomeshjournal.semums.ac.ir/article-1-6171-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 23, Issue 1 (زمستان 1399) Back to browse issues page
کومش Koomesh
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4645